Configured Panel Solutions
Configured Panel Solutions
For retail fueling and convenience store applications, Configured Panel Solutions provide a complete petroleum control and power distribution solution for an entire location.
Highlights
- Configured to a specific site application.
- Replaces Fuel Panel, In-Line E-Stop Contactor, Isolation Boxes, and Pump Control Boxes, plus all associated conduit, wire, fittings and on-site labor.
- A single panel to replace the Fuel Panel and the Emergency Stop Contactor feeding the Fuel Panel.
- Provides AC power controls required for a typical retail petroleum application.
- Includes emergency stop and service disconnects for dispenser low voltage wiring.
- Optional low voltage circuit disconnects.
- Optional series connected surge suppression for protection of sensitive electronic circuits.
- Individual pump and dispenser contactors allow connection of remote control or monitoring system.
- Pump handle isolation using solid state technology.
- Lock-offs on dispenser, pump, and card reader circuits to properly and safely isolate a single device for servicing.
- Provides isolated ground terminations for proper network communications.
- Marked terminals for easy connection of dispensers, pumps, card readers, fuel management systems and tank monitors.
- Door-in-door enclosure to help protect against arc flash.
- Factory assembled and pre-wired, eliminating mounting and wiring of separate components in the field.
AC Power Distribution Capabilities
- Electrical distribution fuel panel.
- Electrical distribution lighting panel.
AC Power Controls Capabilities
- E-stop & reset push buttons
- Emergency stop controls.
- Pump hook isolation.
- Automatic Tank Gauge interface.
- Pump status lights.
- Pump contactors.
- Dispenser contactors.
- Series connected surge suppression.
- Parallel connected surge suppression.
- Lighting controls.
- Third party control devices.
Dispenser Capabilities
- Low voltage disconnect.
- Data circuit protection.
Enclosure Options
- UL Type 1 indoor.
- UL Type 3R outdoor.
Specifications
Certifications/Approvals
- UL Listed.
- cUL Listed.
- For compliance with NEC® 514.11 and NFPA® 30A Section 6.7 requirements for Emergency Disconnects at Motor Fuel Dispensing Facilities (controlled by E-Stop system).
- For compliance with NEC® 514.13 requirements for Maintenance Disconnects at Motor Fuel Dispensing Facilities (switches to disconnect individual dispenser circuits for servicing).
System Components
- Configured Panel Solution
- E-Stop & Reset Operator
- Automatic Tank Gauge
- Submersible Pump Controller
- Primary Disconnect
- Secondary Disconnect
- Open-Bottom Conduit Pedestal (Optional)
Order Info
Ordering Guide
Complete part numbers have a specific order and are created using the following guidelines:
CPS-XDYP L A Q R F P S D/E Z Q P
CPS = Configured Panel Solutions
X = # of Dispensers
1 - 16 = 1 - 16 Dispensers
Y = # of Pumps
1 - 8 = 1 - 8 Pumps
L = # of Lighting Circuits
0 = No lighting Control
L3 = 1 - 4 Conductors
L4 = 5 - 8 Conductors
L5 = 9 - 12 Conductors
L6 = 13 - 16 Conductors
A = A/C Series Surge Protection for Electronic Circuits
0 = No Surge Protection
A0 = Surge Protection*
A1 = Surge Protection, 1 add. circuit**
A2 = Surge Protection, 2 add. circuit**
A3 = Surge Protection, 3 add. circuit**
Q = Main Power
MB10 = 100 Amps Main Breaker
MB15 = 150 Amps Main Breaker
MB20 = 200 Amps Main Breaker
MB22 = 225 Amps Main Breaker
ML10 = 100 Amps Main Lug
ML22 = 225 Amps Main Lug
R = Incoming Electrical Service
1 = 120/240 VAC, 1 Phase, 3 Wire
3 = 208Y/120 VAC, 3 Phase, 4 Wire
F = Feed Connection Location
B = Bottom Feed (Standard)
T = Top Feed
P = Pedestal
0 = No Pedestal
P = Pedestal
D/E = Low Voltage Circuit Disconnects
0 = No Low Voltage Circuits
D = Twisted Pair Circuits
E = Ethernet Circuit Disconnects
Z = Intercom Circuit Disconnects
0 = No Intercom Circuits
C = 1 Speaker, 1 Call Button per Dispenser (4 conductors)
8 = 2 Speakers, 2 Call Buttons per Dispenser (8 conductors)
M = Media Circuit Disconnects
0 = No Media Circuits
E = Ethernet Circuits
C = 4 Conductors, (2) 2-Wire Circuits
8 = 8 Conductors, (4) 2-Wire Circuits
P = Surge Protection for Dispenser Data
0 = No Surge Protection for Dispenser Data
P = Surge Protection for Dispenser Data
*Includes surge protection for dispensers, Automatic Tank Gauges, and site controls.
**For additional circuits such as point-of-sale.
Example:
CPS-4D2PL3A1MB101BPDCEP = Custom Panel Solution, 4 Dispesners, 2 Pumps, 1-4 Lighting Conductors, A/C Surge Protection with (1) additional circuit, 100 Amps Main Breaker, 120/240 VAC, 1 Phase, 3 Wire Incoming Electrical Service, Bottom Feed, Pedestal, Twisted Pair Low Voltage Circuit Disconnects, 1 Speaker, 1 Call Button per Dispenser (4 conductors) Intercom Circuit Disconnects, Ethernet Circuit Disconnects, Surge Protection for Dispenser Data.
Downloads
Featured Downloads
Brochures
| Title | Type | Size | |
|---|---|---|---|
| FFS-0829 Configured Controls Datasheet.pdf | 2.55 MB |
Catalogs
| Title | Type | Size | |
|---|---|---|---|
| FFS-0807 (EN) Product Catalogue.pdf | 153.77 MB | ||
| FFS-0367 (UL) Site Starters Ordering Guide.pdf | 64.42 MB |